Factorio Hosting: No Query Protocol Means No Shortcuts
Most game-server status checks lean on some kind of query protocol. Factorio doesn't have one — which means checking status honestly takes more than one signal, not fewer.
TL;DR
- Factorio speaks its own UDP protocol on 34197 and answers no standard query at all — a foreign packet just gets silence
- The honest check is process-alive AND port-bound together, not either alone
- systemd's “active” status can go green before the world finishes loading and the port binds
A query that was never going to get an answer
A good chunk of game-server tooling assumes some version of a status query exists — Source's A2S being the most common. Factorio implements neither that nor any equivalent; it speaks a protocol of its own on UDP 34197, and anything else sent to that port is simply ignored. There's no error response to catch, no fallback field to read — just nothing, which looks identical to a server that's actually down unless you already know not to expect an answer.
Two signals instead of one query
Without a protocol-level handshake to lean on, the honest check becomes: is the game process actually running, and is UDP 34197 actually bound and listening. Both together is what “joinable” means, since clients connect directly to that IP and port with no intermediary negotiation. Checking only the service manager's state isn't enough either — the unit can register as active before the world has finished loading and the port has actually bound, the same readiness gap that shows up across several other game servers with their own slow-start sequences.
FAQ
Does Factorio answer A2S or any other standard status query?+
No. Factorio speaks its own protocol entirely on UDP port 34197, and a query built for Source's A2S or any other standard protocol just gets silence back — not an error, nothing. Status checking has to work without any query protocol to lean on at all.
How do you check if a Factorio server is actually joinable, then?+
Two signals together: confirming the game process is actually running, and confirming UDP port 34197 is bound and listening. Clients connect directly to that IP and port — so process-alive plus port-bound is what 'joinable' genuinely means here, since there's no protocol-level handshake to ask the server directly.
Why not just check if the systemd service is active?+
Because the unit can go active before the world finishes loading and the port actually binds — the same gap that shows up in several other game servers where the service manager's notion of 'started' runs ahead of the game's own readiness.
A Factorio status badge that means something
CoalHost checks the process and the port together — not a guess based on systemd alone.